| 2007.04.24 |
|
 
Model F series
- HMC-F593A、HMC-F716A、HMC-F403O、HMC-F758O
- PID control for heating and cooling ensures tight temperature control.
Model H series Water high temperature type (up to 120℃)
- HMC-F554H、HMC-F558H、HMC-F754H、HMC-F758H
- PID control for heating and cooling ensures tight temperature control.
|
| |
Features
- Nineteeen percents smaller footprint than our predecessor.
- Larger set value and process value display.
- Almost the same cotrol panel as THD-F series dryer.
- Mold memory allows you to save 100 setups of set value and timer value.
- Start timer is settable up to 99 hours and 59 minutes.(15 hour battery backup)
- Stop timer is settable up to 99 hours and 59 minutes.
- Display power off turns off display during start timer run for energy saving.
- Maintenance notification notifies you when you should service,according to the predetermined time.
- Infrared remote control (option) allows cable-less remote operation.
- Temperature monitor (option) issues alarm if the set value is not reached during the specified time period.
- Returnt temperature monitor (option) display return fluid temperature with differential between the return and supply temperatures.
- Mold memory reset (option) externally changes the current mold memory no. to 00.
- External output indicates what process temperature is normal and/or what differential temperature is normal,in operation.
|
| |
|

|
| |
Option
- Communication with HRX-i series robot
- Fluid hose
- Hose fittings
- Air purge
- 24 hour time switch
- Weekly time switch
- Audible alarm
- Signal light
- RS485 communication
- Mold memory no. reset
- Infrared remote control
- External output
- Temperature monitor
- Different voltage
- Earth voltage breaker
- Remote control input
- External sensor
- Return temperature sensor
- Power plugs
- 4-port manifold
- Cooling water filter
- Custom color
|
| |
Specification HMC F series
| MODEL | HMC-F539A | HMC-F403O | HMC-F716A | HMC-F758O |
| Power supply (v) | 3 phase 200AC(50/60HZ) |
| Fluid | Water | Oil | Water | Oil |
| Temperature control range *1 (℃) | 50〜95 | 60〜160 | 50〜95 | 60〜160 |
| Pump motor | 0.59 k W2P(50Hz/60Hz) | 0.4 k W4P(50Hz/60Hz) | 0.71 k W2P(50Hz/60Hz) | 0.75 k W4P(50Hz/60Hz) |
| Pump type | Multi stage centrifugal | Cascade sealless | Multi stage centrifugal | Cascade sealless |
Pump pressure *2 | 60Hz | 0.38MPa (at 20L/min) | 0.39MPa (at 10L/min) | 0.48MPa (at 20L/min) | 0.76MPa (at 16L/min) |
| 50Hz | 0.24MPa (at 20L/min) | 0.26MPa (at 10L/min) | 0.32MPa (at 20L/min) | 0.56MPa (at 16L/min) |
Pump flow *2 | 60Hz | 50L/min (at 0.28MPa) | 15L/min (at 0.30MPa) | 50L/min (at 0.36MPa) | 46L/min (at 0.15MPa) |
| 50Hz | 50L/min (at 0.16MPa) | 15L/min (at 0.19MPa) | 50L/min (at 0.21MPa) | 39L/min (at 0.15MPa) |
| Heater | 3.0kW | 3.0kW | 6.0kW | 8.0kW |
| Control method | Heating/Cooling PID |
| Rated current | 13A | 12A | 22A | 28A |
| Cooling method | Direct | Indirect | Direct | Indirect |
| Capacity (L) | 1.3(Entire 2.3L) | 2.5(Entire 4.0L) | 1.8(Entire 2.8L) | 2.5(Entire 12.0L) |
| Weight (kg) | 48.0 | 52.0 | 55.0 | 93.0 |
|
- *1.The lower temperature limit of HMC-F 593A&716A canvary with the temperature of supplied water.
- *2.Pump pressure and flow are based on water application.
|
| |
Specification HMC H series
| MODEL | HMC-F554H | HMC-F558H | HMC-F754H | HMC-F758H |
| Power supply (v) | 3 phase AC200(50/60HZ) |
| Fluid | Water |
| Temperature control range *1 (℃) | 50〜120 |
| Pump motor | 0.55kW 2P | 0.75 kW 2P |
| Pump type | Multi stage centrifugal |
| Pump pressure *2 | 60Hz | 0.32MPa (at 13L/min) | 0.41MPa (at 24L/min) |
| 50Hz | 0.23MPa (at 13L/min) | 0.29MPa (at 20L/min) |
| Pump flow *2 | 60Hz | 45L/min (at 0.15MPa) | 75L/min (at 0.21MPa) |
| 50Hz | 35L/min (at 0.14MPa) | 65L/min (at 0.14MPa) |
| Heater | 4.0kW | 8.0kW | 4.0kW | 8.0kW |
| Control method | Heating/Cooling PID |
| Rated current | 14A | 26A | 15A | 26A |
| Cooling method | Direct |
| Capacity (L) | approx.1.2 | approx.2.4 | approx.1.2 | approx.2.4 |
| Weight (kg) | 67.0 | 73.0 | 70.0 | 76.0 |
|
- *1.The lower temperature limit of HMC-F 593A&716A canvary with the temperature of supplied water.
- *2.Pump pressure and flow are based on water application.
|
| |
|